Pci-7344. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Pci-7344

 
 The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environmentsPci-7344 all controllers in the 7344/7334 family

in another word it will show me the STL file is being created layer by layer. com FlexMotion Software Installation Install the FlexMotion software before installing a FlexMotion series motion controller for the first time. I have no choice in using synchro's as feedback. Unfortunately the output pulse has a length of about 20 ms and so I have to decrease the speed of my stage rapidly (otherwise the. 客户使用pci-7344,umi-7764连接第三方的电机和驱动器,搭建了一个闭环控制系统,但发觉电机编码器反馈回的值有些问题. An introduction to the National Instruments PCI-7344 Motion ControllerFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID. all controllers in the 7344/7334 family. Right-click on PCI Device and select Uninstall. baseaddresses[0] is the base-address of the miniMITE and I can get the vendor ID, device ID by directly reading from baseaddresses[0] +offset,but baseaddresses[1] does not like. The linear encoders on the motors are. g. PCI-7344 Servo Products from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, MOTION. The PCI-7342 supports buffered contouring mode. I'm trying to run a device that someone assembled before but the . If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. The NI-Motion version is 7. It is controlled by a host computer with a PCI-7344 motion controller card from National Instrument. 32. We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. All of 3 motors require +5V 24mA for the Mike encoder. Hi, I use PCI-7344 and UMI-7764 and upgrade the motion software and firmware to 7. Overview of the 1-D Interactive Panel. i just need to know if what i write here is correct. . 1, PCI-7344, Amplifier MID-7654, 4 motor-encoders. 問題: 我嘗試要重設位置,但是總是不會歸零。 我的位置總是會被重設到零以外的數值,我該如何將它變為零. Problem 2 The position does not automatically reset to zero when the z. PCI-7344 PCL812PG TRỤC CHÍNH BÀN MÁY CHI TIẾT LỰC KẾ Hình 1. The driver circuits convert TTL level signals for four axes to the ±12 V highconjunction with National Instruments’ PCI-7344 motion controller card and UMI-7764 terminal block. The problem now is: I am not able to wire blocks and delete blocks in the block. flx, but i don't know how to wire it. National Instruments PCI-7314 Driver Download (Official) The PCI-7314 is a device manufactured by National Instruments. A Pivotal Phase 3 Randomized, Placebo-controlled Clinical Study to Evaluate the Efficacy and Safety of the sGC Stimulator Vericiguat/MK-1242 in Adults With Chronic. controller in the 7344 family and contains information concerning their operation and programming. . We have two linear servohydraulic actuators for applying linear force to tie rod and a servo motor for steering wheel movement. The contour trajectory can only be updated every 10 ms, so it is too slow for my application. 能否用NI运动控制卡读取非正交编码器? 硬件: Motion Control>>Controllers>>PCI-7344, Motion Control>>Controllers>>PXI-7344, Motion Control. The cards do not work on a Computer with differen Hardware, nor when the operating system is Windows XP. But. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. all controllers in the 7344/7334 family. I am using: - LabVIEW 8. I have PCI-7344 and PCI-6023E and I want to synchronize them so that my DAQ card will start and stop the acquisition definitely when the motion start and stop. The Hardware limits work as expected. Axis 1) In the Axis Configuration tab, set Type to Stepper. Axis 1) In the Axis Configuration tab, set Type to Stepper. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. The manual of PCI-7344 mentions about by setting blend factor to -1 to get smooth motion path. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. I am using PCI7344 and UMI7774 to do simple control of a motor to make certain movements. Servo motors expect a pulse every . PLEASE, i appriciate any help, because its not working. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. . I checked the files that the person shared with me which are NI-Motion configurations. 1 before, and it is really weird. Axis 1) In the Axis Configuration tab, set Type to Stepper. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. The parameters of that algorithm can be modified, but the algorithm itself is fixed. NI 7340 NI 7342, NI 7344. Actually i want use 2 analog input and create the sample hold vi. Connected to this is a Pepperl & Fuchs 1024 line encoder. 0 system with the newest NI-Motion 7. PCI-7344 PCL812PG TRỤC CHÍNH BÀN MÁY CHI TIẾT LỰC KẾ Hình 1. 4-Axis, Stepper/Servo Motion Controller Device Re: LabVIEWアップデートに伴うPCI-7344のエラー. We have a PCI 7344 motion controller and a UMI 7664 interface. 240 MHz signal. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. Options. PCI-7344, 4-Axis, Motion Control ler National Instruments PCI-7344 Motion Control ler DeviceFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Inst. This will allow you to change the board ID for your hardware so that you can use it to match the configured ID in your code, or. 展开 NI 运动设备 树. The motors are 2 phase and have a 1. Options. The intent is to collect data at each grid point of an X-Y grid. 25 ms corresponding to 0 degrees, 1. Hi, I am using a PCI-7344 with a UMI-7764 to try and control 3 linear actuators and 1 semi-rotary actuator, each of these actuators takes a 0-10v dc voltage and has a feedback signal of 0-10v dc, both input and output being proportional to linear/angular displacement. また、NIのホームパージから. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. Return to Home Page; Toggle navigation; Solutions. After the update the card was not anymore detected in MAX. 0. The x- and y-axes of the Cartesian robot used a timing belt while the z-axis utilized a ball screw. Best regards, baslers. The 7340 uses the same configuration and runs the same firmware as the 7344. Allen C. Dear Engineers, Now we are useing PCI7344 on motor-controlling. The 10 ms timing for contoured move is the fastest that you can get out of the board. 3003 to 7. g. Looking to measure speeds up to 500 RPM. I have seen a few other places where people have asked to do this but have found other solutions. We are using PCI 7344 and UMI 7774. org Mon Sep 8 22:44:35 PDT 2014. freedesktop. . The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. To do so, I would like to write a simple C program to, every specified sampling time T, do the followings: read encoder, calculate output. Click to Contact Seller. There does not appear to be any built-in support for that device. . I am using a PCI-7344 motion controller to control a slide and motor system. Buy PCI-7344: Graphics Cards - Amazon. Hello, I am trying to use both Hardware and Software limits with my motion control system. 10: Sơ đồ khối điều khiển máy Trong khuôn khổ đề tài, bộ điều khiển phay máy CNC 3 trục được xây dựng trên nền một máy PC gắn thêm mạch điều khiển chuyển động PCI-7344 của National Instruments Corp. Options. g. This was a problem at first, because the amplifier is intended for differential outputs, while my encoders have single. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. いつもお世話になっております。 現在,MAX上でモータのチューニングを行っているのですが,以下の4点について教えてください。 (motionボードはPCI-7344,UMIはUMI-7764を用いています) 1,Axis ConfigurationでTypeをServoとした場合に, どのような信号でモータの回転方向(正回転,逆回転)および速度. At times we have seen commands to one axis result in another axis moving. Re: PCI/FW-7344 Motion controller either isn't found or when it is, MAX crashes depending on which version of NI-Motion, DAQ and. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 [email protected] there, I would like to trigger my piezoelectric motor more than 100Hz, can I do that with motion controller PCI-7344/PCI-6036E and using while Return to Home Page Toggle navigationThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. The onboard CPU uses an embedded real-time OS. How can I initialize the device to move with the analog signal from ADC4. PCI-7344 NI module PCI-7344 NI module Module Clips Drive controller servo motor Contact: Mr. Please call or email us with your request. The system works ok, except I have no control over the velocity (does not respond to the vel input vi) as well as there is some hysteresis in the system that provides a large deadband area in the operation about the point where the. Motion Control 7344/7334 Hardware User Manual 7344/7334 Hardware User Manual May 2001 Edition Part Number 322504B-01. When I was using a Motion Controller such as the PCI-7344 which uses the Motion driver, it was possible to save all the motor settings in a . -While controlling the motors in the "Interactive control" tab, the position. 2: I wrote an onboard program that makes a 2axis move and one/two onboard program(s) that write with HighSpeedCapture the Positions to a buffer. Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). Should I setup my limit switches to stop the axis at the limit and then reset encoders there or what? Or should I have a home switch somewhere in the center of travel and let Labview reset the encoders at. 1) connected to a MID-7604 drive to control three IDC P21T stepper motors. >I initialise it using NI MAX (version 2. 10-27-2001 03:20 PM. I have verified the connection is working. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. Using LV 7. Re: problems with a PCI-7344 motion controller. The 7344 can do a frequency of 40 Hz or 78 Hz (which either. Send. Worldwide Technical Support and Product Information National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100The PCI-7344, PXI-7344, PCI-7334, and PXI-7334 controllers are fully compatible with the PCI Local Bus Specification, Revision 2. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. I recently upgraded to MAX version 2. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This means you can create a position profile and download these contouring data to the PCI-7342. Indeed, when we use a newer PCI7344 card, we have driver / firmware compatibility issues. 3. 2. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. Regards, Giridhar Rajan, Automation Engineer Cruiser Controls Mumbai, IndiaThe cheapest NI board that supports elliptical moves in contouring mode is the PCI-7342. STL file there are 28 layers/faces. Dennis_Knutson. While the 7344 can run PID cycles with up to 16 kHz FieldPoint will perform PID loops with about 100 Hz. Options. PCI-7344. Re: PCI-7344 motor interfacing help. As the second option requires three axes, at least a PCI-7344 is required for this method. The 7344 can do a frequency of 40 Hz or 78 Hz (which either may or may. They are tuned and finding the Index position properly. 0. I initialise it using NI MAX (version 2. Software Changes: All of these settings are at Device and Interfaces >> NI-Motion Devices >> Default 73xx Configuration >> Axis x >> Axis Configuration >> Stepper Settings . Dennis_Knutson. Giridhar, everything is ok with your 7344. A declassification procedure for each of these boards would also meet my requirements. いつもお世話になっております。 daqの外部クロック読み込みについて質問があります。 現在、pci-7344およびpci-7764を用いて、サーボアンプからのエンコーダ信号を読み取り、この信号を外部クロックとして、pci-6221に入力する電圧を読み取りたいと思っています。Im using a UMI-7774 and a PCI-7344 motion controller with a Compax C3 servo drive. PCI-7344 National Instruments PCI-7344 National Instruments Module Clips Drive controller servo motor Contact: Mr. The secret is getting the correct Parker-Compumotor Gemini cable that plugs into the. item 5 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 $500. 展开 默认 73xx 设置 树. MAX 5. This means you can create a position profile and download these contouring data to the PCI-7342. Maybe adaptive algorithm, or some other algorithm which I invented. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. In our system, a high resolution encoder works as the feedback sensor, and a third-party of servo works as the velocity loop controller. Mitsubishi A500 inverter driving the motor seems to have only speed (frequency) setting input. Unfortunately the output pulse has a length of about 20 ms and so I have to decrease the speed of my stage rapidly (otherwise the. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. Trusted Enthusiast. If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. I am using a PCI-7344 card with LabView to control a 3-axis servo motor motion system in conjunction with a data acquisition system. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. I encountered problems controlling the motor with MAX using a digital signal. vi as a starting point, I programmed my data acquisition vi to start when the Check Blend Complete. We have successfully done several projects using the Parker-Compumotor Gemini GV servo drive and the NI-7344 and the NI UMI-7764 breakout box. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. But when it comes to the analog output from UMI7774, i can't measure any signal from there while i am sending commands from. National Instruments PXI-7344, 777935-01. 1, FLEX MOTION 5. 2的强大功能,我们得以 在短时间内完成了控制系统的开发,同 时保证了机械臂的运动精度与负载能 力。The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. In the second part, you program for the PCI-7344 controller, which adds several advanced features including the ability to run onboard programs. Author. It includes dual processors, a real-time. The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. Unless otherwise noted, text applies to all controllers in the 7344 family. 9393. When I set it up with the Ni-7344 the drive is ready (green led on drive flashes). 0 and PCI-7344 motor. また、NIのホームパージから. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. Cary, NC,. 展开 PCI-73xx 树. 75 ms. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. Essential details:PCI-7344 NI Motion Controller Device Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National. I have a very strange problem. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Running the motor is not a problem but when it has stopped (there is no load) the servo system still puts out a lot of voltage (+-48V) all the time. . When calling "DIO Port Config. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Use a higher resolution encoder. I have a situation in which the timer_event does not fire. Options. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and. 0. 1. The PCI-7344, PXI-7344, and PCI-7334 controllers are fully compatible with the PCI Local Bus Specification, Revision 2. I would also appreciate one for the Video Capture Board PCI-1409. I have one 3 axes(X,Y,Z) mchine. Environment: MAX 3. The 7344/7334 controllers are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Please let me know if you have any additional questions on this issue. I am currently working on a project related to nanomotion stage control using PCI-7344 and LabVIEW 6. For my research purpose I need some important information from you. Now i´m using the PCI-6527 board and simulating the delay between "high" and "low" on the Simulate-signal-vi. I have tried all the Settings discussed in the Forums and they still don't run. I am trying to figure out the best way to calibrate encoders with the PCI-7344 interface card. 1 and the LabVIEW version is the 8. Explanation, in the help files, is that you can't reset an encoder that is mapped to an axis. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. This makes the motor really hot. 75 ms. 2为开发平台 对3台伺服电机实行位置伺服和编码器 电压的方式实现了角度的反馈控制。借 助LabVIEW8. Figure 7. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. 打开测量与自动化浏览器 (MAX) 导航到您的 NI Motion 设备. Now i am using a PCI-7344 motion controller to control my nanomotion stage. I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. The Motion driver with the PCI 7344 has its own algorithm in place. If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. If you are using LabVIEW, there are many example programs that ship with the NI-Motion driver. 4-axis, step / servo PXI motion controller module - pxi-7344 is suitable for both simple and complex motion applications. comPXI-7344. I am using the PCI-MIO-16XE-50 and PCI-7344. 3-Axis control, stepper motors, closed loop with optical linear encoders. Order international: +1 609. Thank you for your reply !! I am developing pci-7344`s driver under venturecom`s rtx,now I have found the baseadresses[0] and baseadresses[1] . Featured with advanced motion control, handy software tools, and motion VI libraries (to be used with LabVIEW), the NI PXI-7344 (Part Number: 777935-01) is a 4-Axis, PXI Stepper/Servo Motion Control Module. mirror is performed by NI instruments motions controller (PCI-7344), a stepper motor power drive (NI-MID 7604) and a Lab VIEW based program. Select the Servo radio button. 7)and NI-DAQ 7. I've got a PCI card (PCI 7344 for motion control). Conventions National Instruments PCI-7344 Motion Controller Device. cmd_data This an array of six integers used to send parameters and receive values associated with the execution of the specified command. I have one 3 axes(X,Y,Z) mchine. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. . The numbers after VEN and DEV indicate the Vendor. Running the motor is not a problem but when it has stopped (there is no load) the servo system still puts out a lot of voltage (+-48V) all the time. , Austin, Texas) installed in a supportive PC station are integrated using a LabVIEW software package (National Instruments Co. The fact is ,as most say,the driver is not suitable under non-windows systems. We are configuring a new closed loop stepper setup with PCI 7344 and the "Trigger Input occurred" led in MAX is turning red after a search for encoder index. 08-10-2007 01:26 AM. 2をインストールするまでは全く問題なく動作していましたが、Motion Assistant 1. I have one 3 axes(X,Y,Z) mchine. We built the entire machine to industrial standards for ruggedness, reliability, and minimal down time. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. To facilitate learning, we mounted all the motion controlled items, such as three power supplies, two torque amplifiers and oneDescription. Industries. Hardware Using the existing Rhino Robotics Ltd. We have a drive which sometimes needs manual adjustment, so we have to turn off the torque, i. A few month ago, i tried the same, but i lost the code and the motor moves so that the analog signal goes to 0V. 1) How do i know if this motor drive is compatible with the pci-7344 and umi7774 ? for example: inside the UMI manual is written that the Motor drive must support "Sinusoidal Commutation" i. This warranty includes parts and labor. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. ) Issue: W. The CPU-usage rises up to 100%. Pxi-7344 provides hybrid motion trajectory control and fully coordinated circular, linear, point-to-point, gear and vector. sooner or later hardware will be discontinued, OS end of life, LabVIEW version not supported, etc. (The servo drive manual is here:The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. はじめまして。投稿させていただきます。 現在、PCI-7344とUMI-7764を用いて3つのACサーボモータを速度制御しようと考えています。 用いるサーボモータとアンプはそれぞれ、三菱電機製のHC-KFS13と、MR-J2S20A1です。 初歩的な質問をして申し訳ないのですが、アンプとUMI-7764の結線の方法がわかりませ. The machineGood afternoon, I'm using servomotors PSKF321 (SEW) and servodrives MDX61B (SEW). There was a "broken" device PCI-7344 under NI Motion Devices, which status said something like "This device has been removed or could not be detected" and the Res. Lai Wechat:17750010683 Whats app:+86 17750010683Hello, I am fairly new to LabVIEW and was wondering how to implement incremental rotary encoders into a motion control VI. Does this give you any clues? So you are saying this is a bug which was fixed with a patch in earlier LV versions? I didn't find any documentation on this. NI 7330 NI 7332, NI 7334. , Austin, Texas) and a servo motion controller board PCI-7344 (National Instruments Co. All the best-John05-14-2002 08:10 AM. i finally start to understand the setting after i read the PCI7390 which is position-comannd controller. We have just recently switched to a new hardware revision and now all boards don't show up with their specific names but with the name of the board family: Board Family Specific Boards. We have successfully done several projects using the Parker-Compumotor Gemini GV servo drive and the NI-7344 and the NI UMI-7764 breakout box. Current PC config is: Pentium 4 - 2. 20. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. . I am usi. This controller is able to achieve simultaneous three-axis motion trajectories through linear, spherical, circular or helical interpolation, which will placate all our requirements for concurrent three-axis machining and also for the FDM operation. It is related to 3D printer. This could be done in one of three ways: Reduce the number of microsteps. On 2 different systems and 2 different motion control cards (pci-7334 and 7344) after running the cards for approximately 30 minutes I get errorThe PCi 7344 can control a brushless servo provided that the drove for your motor can take a +/- 10 volt torque signal or a step and direction signal as a command signal. Order toll free: 800. PCI-7344. and PCI-7344 motion controller to implement a modular control application that works with an existing robot and four-axis driver. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. It is built using off-the-shelf components (Galil servo motors, PWM power amplifiers with torque-control mode, Lintech manipulator, standard camera). Hello, After having configured mu board PCI-7344 under MAX software (1axis activated because 1 only axis used, standard of stepper in open Loop. I met a problem in using the Labview and it is extremely urgent (I have to make it work in 24hrs). The onboard CPU uses an embedded real-time OS. actually the program has. What would it take to build. The pulse should last from 1. Can I configure another one in the same PC to add more axes to my current system. I continue to get more and more modal errors from the board. Since, I'm waiting in a loop for the Move Complete bit, the program (VB 6. controller in the 7344 family and contains information concerning their operation and programming. I am using LabVIEW 2014 and NI PCI 7344(motion controller). When i am using PCI Flex-6C,Finding home functions does not work as the PCI 7344 do, The controller stops axis 1 and axis 2 during the finding home sequences when the axis 3 encountered home switch first. Hi, I am running a motor using the PCI 7344 motion control board and a MID-7654 servo with encoder feedback. All Manuals. I need to have continuous aquisition at a scan rate of about 10 kHz. including the MAX setting. Problem 1 The encoder counts up and down ok but gives 4096 counts between z pulses and not 1024. 00 shippingi read the ni-motion manual,pci-7344 and umi7774 manual and also the articles about configuring the Position Command mode. MPN. . We are looking for an old PCI 7344 card (4 axis card driving motors) over 15 years old (copyright 2001). The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. We were. 11 PCI 7344 MAX One-axis Configuration 39 3. Analog Output Device. At Lektronix we can provide you with a brand new National Instruments PCI-7344 covered by the Original Manufacturers Warranty. NI-Motion Issue Details I can command my motion controller to move a stepper motor to a target position in Open Loop mode, but when I configure it to run in Closed Loop mode, the motor doesn't appear to complete the move, doesn't move at all,. Unless otherwise noted, text applies to all controllers in the 7344 family. I have verified the connection is working. I'm using the PCI-7344/UMI-7764 to control the motors. I triggered the Measures over RTSI0 with 50Hz(for a. "The polarity of the trigger input is programmable in software as active-low (inverting) or active-high (non-inverting), rising or falling edge. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Hi Im trying to connect an PCI version of the Ni7344 to a Compax C3 servo drive. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. BUT, i though that the pci-7344, and the umi-7774 that i have should handle ALL the operations i need to drive the servo. PCI-7344 cua NI Corp se tch hp hai bo ieu khien servo va step motor. Are you in EU? Call: +44 1782 576800. The reason for the 64-bit operation is a 3rd party function generator card that requires 64-bit LabView to work in conjunction with the 64-bit drivers. I am planning to use PCI-7344 to implement speed control for 7,5 kW induction motor. Member ‎08-12-2003 06:30 PM. My pr. The "Encoder Index found" led is green. NATIONAL INSTRUMENTS NI-PCI-7344. It is related to 3D printer. I recently upgraded to MAX version 2. There is no drive signal to the motor. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. 0. 0 Kudos Message 1 of 3 (5,141 Views) Reply. Product Support, I have recently been using a FW-7344 motion controller to drive an experiment. sawant@gmail. 0 Kudos Message 1 of 7 (4,209 Views) Reply.